Indications
Acute and Chronic Pain
Arthritis
Back Pain
Bursitis
Carpal Tunnel
Fibromyalgia
Ligament Sprains
Muscle Strain
Soft Tissue Injuries
Tendonitis
Tennis Elbow
Peripheral Neuropathy
What’s the technical parameter of hand held class iv laser therapy?
|
Model: |
COZING-T05-6 |
|
Laser Type: |
GaAIAs Diode Laser |
|
Number of Diodes: |
25 |
|
Wavelength: |
650nm*3pcs+904nm*22pcs The wavelength can be selected . |
|
650nm Single laser output power: |
10MW |
|
904nm super pulse laser, the peak output power: |
25000MW |
|
Working Mode: |
Continuous Wave & Pulsed Wave, 1-999HzAdjustable |
|
Frequency: |
1-999Hz can be adjusted |
|
Time: |
1-60 Minutes Adjustable |
|
The max. Output power is |
550 030mW |
|
Power supply: |
DC rechargeable and rechargeable lithium batteries (5200mAh) |
The advantages of COZING-T05-6 hand held class IV laser therapy:
1.Combine 904nm 808nm 650nm into one unit
2.Wavelength can be selected.
3.Humanized design and easy to operated
4. The frequency can be selected.
5.No Side Effects , no trauma
6.The treatment efficiency rate over 90%
7.Highly Effective for Patient (more than 90% efficacy)
8.Superior Alternative to: Analgesics, NSAID’s, Other Medications, Other Modalities
9.Can Reduce the Need for Surgery
Clinical studies
1.Objectives: While low-level laser therapy (LLLT) is not typically included in major knee osteoarthritis (KOA) treatment guidelines, this study aimed to assess whether a dose-response relationship exists for LLLT in the treatment of KOA.
2.Design: Systematic review and meta-analysis.
3.Data Sources: Eligible studies were sourced from PubMed, Embase, the Cumulative Index to Nursing and Allied Health Literature, Physiotherapy Evidence Database, and the Cochrane Central Register of Controlled Trials, as of February 18, 2019. Additional sources included reference lists, books, citations, and expert recommendations.
4.Eligibility Criteria for Study Selection: Only randomized placebo-controlled trials involving participants diagnosed with KOA based on the American College of Rheumatology and/or Kellgren/Lawrence criteria were included. These studies had to apply LLLT to the participants’ knees, with no restrictions based on language.
5.Data Extraction and Synthesis: Data from the included trials were synthesized using random effects meta-analysis and were further subdivided by dose according to the treatment guidelines from the World Association for Laser Therapy. The risk of bias in each trial was assessed using Cochrane’s risk-of-bias tool.
6.Results: A total of 22 trials (n=1063) were analyzed. The risk of bias was deemed insignificant. Overall, LLLT significantly reduced pain compared to placebo, both at the end of the therapy (14.23 mm reduction on the Visual Analogue Scale (VAS), 95% CI 7.31 to 21.14) and at follow-up visits 1-12 weeks post-treatment (15.92 mm reduction on VAS, 95% CI 6.47 to 25.37). Subgroup analysis indicated that pain reduction was more significant with the recommended LLLT doses, both at the end of therapy (18.71 mm reduction, 95% CI 9.42 to 27.99) and during follow-up (23.23 mm reduction on VAS, 95% CI 10.60 to 35.86). The peak reduction in pain occurred during follow-ups 2-4 weeks after treatment (31.87 mm reduction, 95% CI 18.18 to 45.56). In addition, LLLT was also shown to significantly reduce disability. No adverse events were reported.
7.Conclusion: LLLT effectively reduces pain and disability in patients with KOA when applied at doses of 4-8 J with a 785-860 nm wavelength, or 1-3 J with a 904 nm wavelength per treatment spot.
Hot Tags: hand held class iv laser therapy, China hand held class iv laser therapy manufacturers, suppliers, factory, iv laser therapy, class 4 laser therapy, level 4 laser therapy, class iv laser treatment, class iv laser therapy, class 4 medical laser